{"product_id":"digitus-online-tower-ups-module-dn-170132","title":"Digitus OnLine Tower UPS Module DN-170132","description":"\u003ch2\u003eDigitus OnLine Tower UPS Module DN-170132\u003c\/h2\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:auto\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eDescription\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003eDIGITUS OnLine UPS systems reliably protect critical business applications from power outages, voltage fluctuations, and mains interference, ensuring smooth operation. OnLine double-conversion technology continuously stabilizes the power supply and completely isolates it from mains interference. Connected devices receive high-quality, reliable power at all times, regardless of the power grid quality. In the event of a power outage, the UPS responds immediately and smoothly. This ensures systems are protected and ready for operation, while also providing sufficient time for a controlled shutdown. This minimizes risk, prevents data loss, and protects valuable equipment. Thanks to its compact tower design, the UPS can be flexibly integrated into a wide range of environmentsfrom offices, server rooms, and professional infrastructures. High efficiency and space-saving design make it an ideal choice for modern work environments. The integrated display and various interfaces enable easy integration with existing systems, as well as convenient monitoring and control. Combined with its robust design and reliable technology, it offers a long-term solution for maximum operational reliability. Uninterruptible Power Supply with 0 ms transfer time Pure sinewave output voltage with high voltage stability to protect sensitive devices from interference and failures Space-saving and high-performance - ideal for small server rooms and business environments Wide input voltage range reduces battery consumption and increases battery life in unstable electrical conditions Optimized charging management ensures longer battery life and faster recovery after a power outage Multiple protection features: Short circuit, overload, overheating, overcharge, and deep discharge, low output voltage alarm, and fan fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eApparent power\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003e3000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eActive power\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eUPS Architecture\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003eon-line double conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eThe shape of the output voltage\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003eFull sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eNumber of phases input\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003e1 (230V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eNo. of batteries\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eVoltage\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eBattery capacity\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eCharging time\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eChassis type\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003eTower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eFilters \/ protection\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003eOverheating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eFilters \/ protection\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003eOvercharging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eFilters \/ protection\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003eVoltage drop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eFilters \/ protection\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003eOverload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eFilters \/ protection\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003eOverdischarge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eFilters \/ protection\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003eCircuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eInput power ports\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003eType F Schuko\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eOutput power ports\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003e8 x IEC-C13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eI\/O connectors\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003e1 x USB (Type B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eI\/O connectors\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003e2 x RJ-45 LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eI\/O connectors\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003e1 x RS-232 (COM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eEnvironment requirements\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003eOperating Temperature (°C): 0 ~ 40 Storage Temperature (°C): -25 ~ 55 Humidity Range: 20 ~ 95% RH at 0 ~ 40 °C (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eAccessories included\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003eOnLine, Tower UPS Systems, 3000 VA\/3000 W Power Cord USB Cable RS232 Cable Quick Installation Guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eColor\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003e191 × 460 × 337 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003e24.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" style=\"width:35%;text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;white-space:normal\"\u003eOther features\u003c\/th\u003e\n\u003ctd style=\"text-align:left;vertical-align:top;padding:8px;border-bottom:1px solid #ddd;overflow-wrap:anywhere\"\u003eInput: IEC60320 C20 socket, 208\/220\/230\/240 VAC Output: 8 x IEC60320 C13, max. 10A per socket, 1 x IEC60320 C19, max. 16A Input: Nominal voltage (VAC): 208\/220\/230\/240 Operating voltage range (VAC): 110 ~ 300 (176 ~ 264 at 100% load) Power factor: 1.0 Bypass frequency range (Hz): 40 ~ 70 (50 \/ 60) auto-sensing Output: Nominal voltage (VAC): 208\/220\/230\/240 Voltage regulation: 1% Output frequency (Hz): Mains operation: 46 ~ 54 or 56 ~ 64; Battery Operation: (50\/60 0.1%) Crest Factor: 3:1 Total Harmonic Distortion (THDv): 3% with linear load; 5% with non-linear load Switching Time (ms): Switching from mains to battery: 0; Inverter to Bypass Transfer Rate: 4 (typical) Waveform: Pure Sine Wave Efficiency: On-line: Up to 92% \/ ECO: Up to 97% Battery Type: VRLA (Maintenance-Free Lead Acid) Battery Voltage (Vdc): 72 Charging Current (Max) (A): 2 Generator Compatible Cold Start Feature Typical Recharge Time (hours): 4 (to 90% of full capacity) Network Connection: Optional SNMP\/Webcard (part number DN-170100-1) allows remote monitoring of the UPS. Local Communication Ports: USB, RS-232 (serial), SNMP (optional) Operating Altitude (m):\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Digitus","offers":[{"title":"Default Title","offer_id":54336637731163,"sku":"AUASSL2T0000011","price":536.93,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0865\/0152\/3803\/files\/AUASSL2T0000011-1.jpg?v=1791835087","url":"https:\/\/prime-electronics.eu\/de\/products\/digitus-online-tower-ups-module-dn-170132","provider":"Prime Electronics","version":"1.0","type":"link"}